Bathrooms and ensuites
The room most people ask about first, because tile underfoot reads cold whatever the air temperature says. Small areas, regular shapes, usually a mat.
Tile, stone, wet rooms
Mats
A warm floor in the room that wants one. Mat or cable in the build-up under tile, stone or an engineered covering, its own thermostat on the wall, and nothing added to the mechanical room.
Heating elements sit in the floor build-up beneath the finished covering. The room has a thermostat of its own, and the rest of the house does not need to know about it.
This is the comfort job. One room, or a few, sized against the area of floor rather than against the heat loss of a building, and switched by the person standing in it.
Mat where the layout is regular, loose cable where it is not. A floor sensor reads the slab or screed temperature and the thermostat runs to that number, so the floor holds a temperature rather than chasing the air.
Everything that decides how the floor performs — the area, the watt density, the spacing, where the sensor sits — is settled on a layout drawing before a reel is opened. That drawing comes back with the quote.
Heating a whole building from the concrete it stands on is the same technology at a different scale, and it has its own page. Electric in-slab heating
Named by the room rather than the part code. The Danfoss line behind each one is on the right.
The room most people ask about first, because tile underfoot reads cold whatever the air temperature says. Small areas, regular shapes, usually a mat.
Tile, stone, wet rooms
Hard flooring in the rooms that take the weather in off the street. A heated floor dries what gets tracked in rather than leaving it to sit.
Kitchens, entries, mudrooms, halls
A floor above a garage, a crawl space or an open porch loses heat downwards all winter. Warming the floor itself treats the surface people actually touch.
Over garages, crawl spaces, porches
A renovation where the covering is coming up anyway is the moment the system costs least to add. Each area runs off its own thermostat, so the work can stop at one room and still be finished.
Renovations, single rooms, phased work
Manufacturer figures for the LX line, from the Danfoss catalogue. Values Danfoss publishes only per product are settled on the layout drawing that comes back with the quote.
The system goes in once, under a covering nobody will lift again for decades. The resistance readings are the part a general trade tends to skip, and they are what the warranty file rests on.
Every job starts as a drawing.
Area, watt density, spacing, sensor position and connected load are settled on paper first, because the covering goes down on top of the cable and the layout cannot be revised afterwards.
Dry-Ways supplies the system and can install it. Where another contractor is doing the work, the layout, the load and the test regime are still issued with the order, because the warranty depends on them.
Heat goes both ways. Insulation under the heated build-up is what sends the output up into the room instead of into the structure below it.
Ohm reading taken before anything is unrolled, to prove the cable did not take damage in transit.
Mat or cable set out to the spacing the layout drawing calls for, with the floor sensor in a conduit so it can be replaced without lifting the covering.
Second reading once everything is fixed and the cold leads are run back to the panel.
The final reading is the last chance to find a fault, and it is what closes the warranty file. It is the same three-reading regime a slab gets.
Thermostat and floor sensor set to a floor temperature. Where the covering manufacturer publishes a maximum surface temperature, that limit governs and the thermostat is set under it.
Electric can eliminate boilers, pumps, glycol and other mechanical components. Depending on the application that can mean less equipment, simpler installation and lower project cost, and fewer maintenance requirements.
No boiler, no pump, no manifold, no fluid. There is no annual service call on a cable under a floor, and nothing to bleed or refill.
Each area runs off its own thermostat and only draws power when that room calls for heat, rather than driving one loop for the whole building.
Product, layout, spacing, output and system requirements are engineered for the job before anything is ordered, and the drawing comes back with the quote.
Five answers specific to heated interior floors. The general questions are on the homepage FAQ.
Not here? Send us the job or call 780-953-9297.
Scale and where the heat sits. Interior floor systems warm the floor of a room, in the build-up under the covering, run from a thermostat in that room. Electric in-slab heating puts the cable inside the concrete the building stands on, so the slab becomes the emitter and can carry the heating load for the whole space. Same technology, different job, and the choice is usually made by what stage the construction is at.
Commonly, but the manufacturer of the floor covering sets a maximum surface temperature and that limit governs the design. Tile and stone conduct best and are the usual finish. Send us the covering you have chosen along with the room.
For most rooms it is comfort heating and something else carries the load. Whether a floor system can be the heat source for a given room is a heat-loss calculation rather than a preference, and that calculation is part of the quote.
Yes. Each area has its own thermostat and its own circuit, so the rooms are independent. The economical moment for any one room is while its covering is up.
It runs through the heating season rather than per event, so the figure is part of a heating bill. The running cost panel on the homepage is built for the snow-melting case and does not answer this one.